2147
SUPERSAN RENDER

Formerly Name change (available during the year). Previous product 2747.

Preserving treasures

For protecting our cultural monuments

  • Dehumidifying plaster: for drying very damp walls in historical buildings. With high water transport capacity.
  • Very vapor permeable to transport moisture.
  • For substitution of chemical injections in cultural monuments.
  • For the restoration of damp walls with high salt content: transports the salt to the surface so that it can be brushed away.
  • Can be used as a sacrificial plaster that absorbs moisture and salt, then removed and replaced.

Area of application

  • Outdoors: wall + ceiling
  • Indoor: wall + ceiling
  • Suitable for monuments and historical buildings
  • Vapour permeable

Processing method

  • For hand processing
  • Special drying plaster for the rehabilitation of wet masonry.
  • For high salinity and wet areas.
  • For stone, brick and mixed masonry.
  • For basements and walls below ground level.

Price list

Code

Packaging

Code

BC4 084 25 20 02VN

Packaging

25 kg

Kontakty

Processing details

Learn more about technical details for processing this product.

Substrate requirement

The substrate must comply with the applicable standards, must be solid, free of loose particles, free of dust, paint, residues of demoulding substances and efflorescence. It must be sufficiently rough, dry and evenly absorbent. The surface shall not be frozen or water-repellent. The substrate must be stable in volume.

Substrate preparation

Depending on the absorbency of the substrate and the climatic conditions, it needs to be moistened. Coat the substrate with pre-sprinkleri prepare from material Cemix 2147. The pre-sprinklering must be done in its full area. The substrate must be dampened before plastering.
If necessary, treat non-standard substrates with a suitable method to achieve the desired properties. The substrate must comply with applicable regulations, standards or material manufacturer's recommendations.

Preparation of the mixture

Prepare the material by pouring the dry mixture into the prescribed amount of water and mixing it. Use potable water or water complying with EN 1008 to mix the mixture. Mix using a drum mixer. Mix to a homogeneous mixture without lumps.
In case of preparation of the pre-sprinkler, the mixing time is max. 10 minutes. You set the watery consistency only in the last minute of mixing.

Water demand

CEMIX_blue_handling_water-quantity_25kg_3,25-4,0l
Quantity Liters (Min) Liters (Max)
1 kg 0.13 L 0.16 L
25 kg 3.25 L 4 L

Mixing

CEMIX_blue_handling_swirl_15min
Mixing time
15 min

Processing instructions

Apply the plaster to the surface with a trowel or other suitable tool. Then roughly flatten the surface with a squeegee to the desired level. Once the plaster has set, open the plaster flat with a suitable tool. A minimum curing time of 1 day per 1 mm of applied layer is considered. The plaster forms a base and levelling layer for the stucco or final finish. The plaster must not be left untreated in the exterior for long periods (especially over the winter period).

Application thickness

CEMIX_blue_techdata_30_15mm
Minimum layer thickness 15 mm
Recommended layer thickness 25 mm
Maximum layer thickness 30 mm

Consumption

CEMIX_blue_techdata_trowel_1,25kg-1mm
Material consumption min.
1.25
Material consumption max.
-
Material consumption in measuring unit
kg/m²/mm

Consumption renders

Structure Consumption in Kg per m²
Sanační omítka v tl. 25 mm 31,25

Yield

Material consumption at unit Yield
25 kg 25 mm 0,80 m²

Working time (potlife)

CEMIX_blue_handling_trowel_60min

60 min

Treatment after application

After application, the direct negative effects of sun, heat, humidity and draughts should be avoided. Protect from frost and rain. Direct heating of the surface is prohibited.

Tool and cleaning instructions

Wash off tools with water immediately after finishing work. Clean dried residues mechanically.

Technical parameters

Main binder Grey cement
Made of material Mineral filler, cement, special additives to improve processing and performance properties.
Flammability class A1
Max. grain size 2mm
Adhesion after dry storage in ≥N/mm²(ETAG004) 0.2
Thermal conductivity λ in W/(m.K) 0.36
Water vapour diffusion resistance factor µ 12
Dry bulk density in Kg/m³ 1100
Dry bulk density in Kg/m³ to 1400

Download

Technical datasheet

Contact: Can we help you?

Ask us your question. Write to us whenever you want. We will reply within 48 working hours.

Telephone 800 022 848

Contact us on the toll-free Customer hotline

  • Opening hours: weekdays 7:30 a.m.–3:00 p.m.
  • Email: info@cemix.cz
     

Contact form