2150
LIME PRE-SPRINKLER
Formerly Name change (available during the year). Previous product 2750.
For the professional preservation of monuments
Strong hold for lime base plasters
- Coarse texture: Surface treatment to improve the adhesion of pure lime base plasters.
- Lime-based and cement-free: For plastering of historical buildings made of classic masonry materials (brick, natural stone).
- Contains pozzolan: Reduces efflorescence and prevents from stains.
- Diffusion open: Highly vapour permeable for a good room climate. With natural anti-fungal properties.
- Good adhesion: lime based with puzzolan additives.
- Suitable for renovations and new buildings.
Area of application
- Outdoors: wall + ceiling
- Indoor: wall + ceiling
- Suitable for monuments and historical buildings
- Vapour permeable
Processing method
- For hand and machine processing
- Contact bridge for stone, brick and mixed masonry before lime plaster application. For internal and external use.
Price list
Code
Packaging
Code
BC4 144 25 20 02VN
Packaging
25 kg
RECOMMENDED SYSTEM PRODUCTS
Processing details
Learn more about technical details for processing this product.
Substrate requirement
The substrate must comply with the applicable standards, must be solid, free of loose particles, free of dust, paint, residues of demoulding substances and efflorescence. It must be sufficiently rough, dry and evenly absorbent. The surface shall not be frozen or water-repellent. The substrate must be stable in volume and must have the required flatness.
Substrate preparation
Depending on the absorbency of the substrate and the climatic conditions: very absorbent substrates must be moistened. If necessary, non-standard substrates should be modified by a suitable method to achieve the required properties. The joints of the old masonry are scraped to a depth of approx. 20 mm. The substrate must comply with the applicable regulations, standards or recommendations of the material manufacturer.
Preparation of the mixture
Prepare the material by pouring the dry mixture into the prescribed amount of water and mixing it. Use potable water or water complying with EN 1008 to mix the mixture. Mix using a slow speed propeller mixer. Mix to a homogeneous, lump-free mixture and leave to rest. Then mix again briefly. Use suitable machinery when processing by machine.
Water demand

Quantity | Liters (Min) | Liters (Max) |
---|---|---|
1 kg | 0.25 L | 0.29 L |
25 kg | 6.25 L | 7.25 L |
Mixing


Processing instructions
When applied by hand, the spray is applied to cover approximately 75% of the masonry with a mason's spoon or ladle. The maximum layer is 5 mm. For machine application, we recommend the use of an older pump unit with a higher wear rate, as the rotor/stator can pump the grain size of the material more easily. Highly absorbent substrates should be moistened with water before spray application.
Application thickness

Minimum layer thickness | 3 mm |
---|---|
Recommended layer thickness | 4 mm |
Maximum layer thickness | 5 mm |
Consumption

Consumption renders
Structure | Consumption in Kg per m² |
---|---|
krytí 50-75 % podkladu v tl. 4 mm | 3,38 |
krytí 100 % podkladu (celoplošně) v tl. 4 mm | 5,40 |
Yield
Material consumption | at | Yield |
---|---|---|
25 kg | 4 mm (krytí 50-75 % podkladu) | 6,01 m² |
25 kg | 4 mm (krytí 100 % podkladu) | 4.63 m² |
Working time (potlife)

120 min
Treatment after application
Non-absorbent materials prolong the maturation period.
After application, the direct negative effects of sun, heat, humidity and draughts should be avoided. Protect from frost and rain. Direct heating of the surface is prohibited.
Tool and cleaning instructions
Wash off tools with water immediately after finishing work. Clean dried residues mechanically.
References
Technical parameters
Main binder | Lime hydrate |
Made of material | Aggregate, pozzolanic binder, lime hydrate and additives improving the processing and utility properties of the plaster. |
Flammability class | A1 |
Max. grain size | 2mm |
Adhesion after dry storage in ≥N/mm²(ETAG004) | 0.2 |
Liquid water permeability | W1 |
Thermal conductivity λ in W/(m.K) | 0.52 |
Water vapour diffusion resistance factor µ | 15 |
Dry bulk density in Kg/m³ | 1400 |
Dry bulk density in Kg/m³ to | 1600 |