5500
SELF LEVELLING COMPOUND

Formerly Self levelling compound

For perfectly even floors

Reliable self-leveling indoors

  • Self-leveling: Highly flowable and easy to apply. For perfectly even substrates under floor coverings.
  • 2-10mm application thicknesses, locally up to 15 mm, in one operation.
  • Useable for wet areas like bathrooms.
  • Suitable for floor heating.
  • Walkable after 6-8hrs.
  • Tileable after 4 days.

Area of application

  • Indoor: floor
  • For humid areas

Heating and cooling area

  • Floor

Processing method

  • For hand and machine processing
  • For levelling interior floors before laying floor coverings (tiles, floating floors, PVC, carpets, etc.).
  • For levelling concrete floors.
  • For using heating cables and mats for electric underfloor heating, including levelling cement screed surfaces with built-in hot water heating.
  • The compound is not recommended for high load floors and floors subject to traffic loads; it is not intended as a final utility layer.

Processing details

Learn more about technical details for processing this product.

Substrate requirement

The substrate must comply with the applicable standards, must be solid, free of loose particles, free of dust, paint, residues of demoulding agents and efflorescence. It must be sufficiently rough, dry and evenly absorbent. The surface shall not be frozen or water-repellent. The substrate shall be stable in volume.

Substrate preparation

Depending on substrate water absorption and climatic conditions, the following is needed: Use Cemix 5400 primer on absorbent substrates, roughen smooth substrates or use Cemix 8040 contact bridge. For non-standard substrates, modify with a suitable method to achieve the desired properties. Smooth out large unevenness in the substrate with appropriate Cemix materials and allow to dry and cure. The substrate shall comply with applicable codes, standards, or material manufacturer's recommendations.

Preparation of the mixture

Prepare the material by pouring the dry mixture into a suitable machine with the prescribed amount of water. Use potable water or water complying with EN 1008 to mix the mixture. Mix to a homogeneous mixture without lumps.

Water demand

CEMIX_blue_handling_water-quantity_25kg_5,0-5,5l
Quantity Liters (Min) Liters (Max)
1 kg 0.2 L 0.22 L
25 kg 5 L 5.5 L

Mixing

CEMIX_blue_handling_swirl_5min800x CEMIX_blue_handling_rest_3min
Mixing time
5 min
Mixing speed in Rpm
800x/min
Ripe time
3 min

Processing instructions

After evenly spreading on the substrate, the layer is leveled, spread to the desired thickness using a fine-toothed spatula or trowel. The laid mixture is then blown off with a hedgehog roller, which also helps to level it. In the case of machine processing, the mixing is carried out, for example, with an m-tec duo-mix with accessories recommended by the manufacturer for the application of self-levelling floor compounds. The hose outlet must be equipped by a filter to catch dirt.
The screed can be used to water electric heating floor mats only under the conditions of strict compliance with the ramp-up cycles specified by the heating mat manufacturer. The covering layer of the screed must be at least three times the thickness of the heated cable. Local levelling of unevenness may be up to 15mm.

Application thickness

CEMIX_blue_techdata_10-2mm
Minimum layer thickness 2 mm
Recommended layer thickness 4 mm
Maximum layer thickness 10 mm

Consumption

CEMIX_blue_techdata_trowel_1,7kg-1mm
Material consumption min.
1.7
Material consumption max.
-
Material consumption in measuring unit
kg/m²/mm

Yield

Material consumption at unit Yield
25 kg 4 MM 3.8 m²

Working time (potlife)

CEMIX_blue_handling_trowel_20min

20 min

Walkability after

CEMIX_blue_handling_trespass_6h

6 h

Treatment after application

After application, the direct negative effects of sun, heat, humidity and draughts should be avoided. Protect from frost and rain. Direct heating of the surface is prohibited.
The surface is walkable in about 6-8 hours after application, full load after laying floor coverings. Laying of floor coverings can be done after the screed has dried to the required value according to ČSN 74 4505. Under normal conditions the screed requires 1 day per 1-2 mm thickness to dry to equilibrium moisture content.

Tool and cleaning instructions

Wash off tools with water immediately after finishing work. Clean dried residues mechanically.

Technical parameters

Main binder Grey cement
Flammability class A1fl
Max. grain size 0,7mm
Full load after 7 d
Compressive strength 28 days in N/mm² 20 N/mm²
Flexural strength 28 days in N/mm² 5 N/mm²
Thermal conductivity λ in W/(m.K) 1.2
Dry bulk density in Kg/m³ 1850
Dry bulk density in Kg/m³ to 2050
Release of corrosive substances CT

Download

Technical datasheet
Simple Transactional Email